Open, and the first look is free · 9am–5:30pm, Mon to Fri Quicker to ring: 0800 6890668
RDR Reading Data Recovery 0800 6890668 Get it quoted
RDR / Casebook / It Would Not Save, Then It Would Not Open

Flash and SSD · job record · RDG-2025-2068

Saving Failed in March, Opening by June.

One stick held everything a Theale family historian had put together for her clients: parish registers photographed page by page, catalogues from old sales, and the memories of the village's older residents, typed up across several winters. The failure arrived in stages. Back in March the laptop she takes to appointments would not accept anything new. Folders began refusing to open in June. The only thing it produces now is USB device not recognized.

Published with the customer's agreement Customers are never named

Same fault on yours? Tell us what it is doing.
0800 6890668

What actually caused it.

That order of events is the answer in itself. Flash wears out through writing; reading costs it nothing. A cell gives up a little of its life to every program-and-erase cycle, while fetching a page back takes none at all — so a stick that stopped saving in March and stopped opening in June has simply been used up. The controller conceals the early part of that. Tired blocks get retired quietly for as long as there are spares to draw on, and the translation tables live on whatever silicon is still dependable. Run out of spares and those tables have nowhere to sit, at which point the stick goes quiet on the bus. On screen you get a controller with no further answers in it, and that says nothing whatever about the scans.

What this one needed on the bench.

How every job runs →
Bench toolsIts part in this jobWhy it is here
PC-3000 FlashMatched the NAND against the library, lifted it off the board and read the die directlyReads the NAND direct, past the controller, against a maker-ID library kept current
Rusolut Visual NAND ReconstructorPeeled off the XOR mask, then put the pages back in the controller’s own orderError correction, XOR mask, page order, reassembly — a raw NAND dump turned back into files
R-Studio TechnicianReassembled the FAT volume, and her own naming came back with itHandles almost any file system, and puts an array back together off the images

What the bench did.

01

Which had failed first, the flash or the controller

USB returned nothing whatever. Off came the casing, and probes went onto the board. Approached direct, the memory answered straight away, and its part number was already in our library. The controller beside it stayed silent — which the order the symptoms had arrived in, writes first and reads later, had pointed at from the beginning.

02

Pull the pages first, work out the order later

What a chip read gives you is a long way from a disk image. The error-correction bytes come attached to every page, an XOR mask of the controller’s own choosing sits over the lot, and the ordering is whatever a translation layer that no longer exists decided on. Three things then have to go right: correct the errors, lift the mask, restore the order. All three and the files appear; one of them wrong and the output is noise.

03

Rebuild the volume, then check each item opens

Errors corrected and the order restored, the FAT tables read out cleanly and the archive appeared under the names she had given it. Every item was then opened by hand — the registers, the sale catalogues, the typed-up interviews. Counting files proves very little on its own; if a thing will not open, it has not come back.

What went back.

Fresh media carried the whole archive home. Three copies is the rule she works to now, one of which never leaves the house it lives in. The worn stick is still in a drawer, kept as a reminder of which way round the two failures came.

The short version: Once a stick stops taking new files there is very little left in it. Copy the contents the same day rather than four months on. The look is free, cards and USB sticks are £250 + VAT, and that figure is confirmed in writing before anything starts.

If that sounds like yours, stop there.

Post it in as it is, switched off. Looking costs nothing, and you get one fixed figure in writing before any chargeable work begins — £250 + VAT for a card or stick, £300 + VAT for a single drive, from £500 + VAT for RAID and NAS. On most jobs, nothing is charged unless your data comes back.

0800 6890668