A rebuild that halted on a six-bay PowerEdge, and two volumes back
An engineering consultancy at Didcot had run a six-bay PowerEdge a member short since the summer without anybody noticing. When a second carrier went amber, a spare was fitted and the rebuild allowed to run; it halted part-way and the virtual disk went offline. The chassis was powered down that afternoon and every drive came in with its bay number written on the carrier. The two weak members were copied first, one of them across four passes, and the rest read straight through. The PERC's own description of the set was lifted off the images, the array assembled above them, and both volumes — the file share and the job database — brought up read-only. Everything was opened here before it went home.